pH and conductivity meter supplier in Bangladesh

Tell Roptan, your pH and conductivity meter supplier in Bangladesh, where you measure and what range you need. We source bench, portable and inline meters with their probes, buffers and standard solutions from verified sellers, check them and deliver.

  • Verified sellers
  • Checked before it ships
  • Delivered by Roptan

Get ph and conductivity meters sourced

Prefer to deal with suppliers yourself? Post it on the requirement board

Buying ph and conductivity meters in Bangladesh

A pH meter reads how acidic or alkaline a liquid is; a conductivity meter reads how well it carries current, a guide to dissolved salts. In Bangladesh, effluent plants at dyeing and washing mills check discharge, boiler houses watch feed water and blowdown, and laboratories test samples.

A meter is only as good as its probe and its last calibration, so a pH and conductivity meter supplier in Bangladesh should send the right buffers, standards and spare probes with it. Tell us the liquid, the range and where you read it. We source from verified sellers, check the probe and certificate, and deliver.

Kinds of pH and conductivity meter

Benchtop pH meters

For samples carried to a laboratory. Choose one when samples from several points can be tested at one bench.

Portable pH meters

For readings on site, at a tank, drain or well. Choose one for spot checks around a plant where no continuous record is needed.

Inline pH analysers

Read continuously in a pipe or basin and can feed a control system. Choose one where the process must respond to the reading without waiting for a person.

Electrode conductivity meters

Use cells with two or four electrodes. They suit low and moderate conductivity, such as drinking water; flexible cells with variable electrode spacing also read strongly conductive solutions.

Inductive conductivity sensors

Measure by induction rather than through electrode contacts, and suit harsh chemical conditions. They need a larger sample volume, so they belong in pipes and tanks rather than sample cups.

TDS meters

Conductivity meters that convert the reading to total dissolved solids with a factor that varies with the salts present, so ask which factor the meter uses and whether you can change it.

How to brief a pH and conductivity meter supplier in Bangladesh

Where the reading is taken
Laboratory, field or in the process. This decides bench, portable or inline, and whether you need a signal to a control system.
pH probe
Many meters use a combination probe, glass and reference electrode in one body; separate electrodes, or an antimony electrode for rough conditions, also exist.
Conductivity range
Drinking water usually reads a few hundred µS/cm and sea water about 50 mS/cm, so a meter for one will not cover the other. Give the range.
Reference temperature
Conductivity changes with temperature, so readings are reported at a reference, usually 25 °C, sometimes 20 °C. Match the one your testing laboratory uses.
Cell constant and standards
Ask for the cell constant on the certificate and potassium chloride standard solutions with the meter, since the constant is found by calibrating in a known solution.
Buffers and spares
Buffer pH shifts with temperature, so ask for buffers with a stated value at your working temperature. Effluent fouls probes, so keep a spare electrode for each inline point.

Standards, tests and paperwork

ISO 10523
The laboratory method for the pH of water. It covers the measurement, not the meter.
IEC 60746-2 and IEC 60746-3
Set out how pH and conductivity analyser performance is expressed. Ask whether the datasheet follows them.
OIML R 54 and OIML R 68
R 54 gives pH values for buffer solutions from 0 to 95 °C; R 68 gives a calibration method for conductivity cells.
ECR 2023 and laboratory tests
ECR 2023 sets effluent discharge limits that include pH. A Department of Environment laboratory report from July 2026 measured pH by APHA method 4500-H+ B, so the official figure comes from a lab.

What moves the price of a pH and conductivity meter

  • Format: pen and portable meters usually cost less than benchtop meters and inline analysers.
  • Resolution and accuracy: finer readings cost more.
  • Features: automatic temperature compensation and data logging add to the price.
  • Probe and cell: the conductivity range of the cell and the probe material move the price.
  • Consumables: replacement probes and solutions are a running cost; price them with the meter.

Lead times and delivery

Lead times vary with the format and whether the seller holds the meter in Bangladesh or imports it, which adds freight and clearance at Chattogram. Order buffers, standards and a spare probe with the meter so a dead electrode does not wait for a second shipment. Roptan confirms dates and the minimum in the quote.

We deliver anywhere in Bangladesh. Bench and portable meters arrive with probe, buffers and standards, checked by a calibration on delivery. For inline analysers, the seller mounts the probe, wires the transmitter, calibrates on site and checks the signal. You receive the certificate, manual, warranty terms and a VAT invoice (Mushak 6.3).

What we check for this order

  • Probe and cell against the datasheetWe check the probe type, the cell and its constant match the datasheet and your range.
  • Solutions in dateWe check fresh buffer and standard solutions are included, sealed and within their dates.
  • Calibration on deliveryWe check a two-point pH calibration passes and the slope is healthy before the meter is handed over.
  • Certificate pointsWe check the certificate lists the points tested and, for conductivity, the cell constant.

Questions buyers ask

Can my plant pH meter replace the laboratory test for DoE?

No. Effluent compliance under ECR 2023 is shown by a laboratory test, and the DoE laboratory report cited above used APHA methods for pH and TDS. Your own meter is for control and early warning: it tells you to act before a sample fails. Keep its calibration log alongside the lab reports.

How do I know a pH electrode is wearing out?

Watch the calibration slope. A glass probe gives about 0.06 volt per pH unit, so a falling slope during two-point calibration is a warning. Clean the probe for the contaminant first: salt, grease and a clogged junction each need a different step. If the slope stays low, fit the spare.

Which conductivity meter does a boiler house need?

Usually one for feed water and blowdown, separate from any effluent meter, since boiler blowdown is commonly monitored for conductivity continuously. Give the water source, the expected conductivity range and the reference temperature you report at, so the cell and range match the water rather than the effluent.

Why do two meters give different readings on the same sample?

Usually temperature, calibration or a dirty probe. Buffers change with temperature, conductivity must be corrected to the same reference temperature, and TDS meters may use different factors. Calibrate both with the same fresh solutions at the same temperature, then compare.

How soon will I hear back about measuring instruments and meters?

Within 48 hours of a complete requirement, with a price and a delivery date. A requirement is complete when it has the model or specification, where it is needed and by when.

Who do I deal with?

With Roptan, when Roptan manages the order: we buy from the verified seller and deliver to you. With the supplier directly, when you post on the requirement board and choose a quote yourself.