Managed sourcing from Bangladesh, for export and for buyers at home
Get it sourced

Machinery and handling · Measuring instruments and meters

Flow meter supplier in Bangladesh

Send the liquid, pipe size and flow range to Roptan, your flow meter supplier in Bangladesh. We source electromagnetic, ultrasonic, vortex and fuel meters from verified sellers, check the datasheet and calibration certificate, and deliver.

  • Verified sellers
  • Checked before it ships
  • Delivered by Roptan

Get flow meters sourced

Prefer to deal with suppliers yourself? Post it on the requirement board

Buying flow meters in Bangladesh

A flow meter measures how much liquid or gas passes through a pipe, as a rate and a running total. In Bangladesh, effluent plants, dyeing mills, boiler houses and water projects use them to measure water drawn, effluent discharged, steam raised and fuel burnt by generators and boilers.

Ask a flow meter supplier in Bangladesh for a model and you may get one that cannot read your liquid: a meter that works on effluent can fail on diesel. Tell us the liquid, temperature, pressure, pipe and range. We match the principle, source from verified sellers and check the papers; the seller commissions inline meters.

Kinds of flow meter

Electromagnetic flow meters

For liquids that conduct, inside a non-conducting liner: water, effluent and sludge, not oils. The pipe must run full and the electrodes must resist the liquid. Some models clean their electrodes in place.

Ultrasonic flow meters

Clamp-on transit-time units strap to the outside of a pipe and suit clean liquids on lines that cannot stop. Doppler units need bubbles or particles to reflect the sound, so they suit dirtier liquids.

Vortex flow meters

Count the vortices shed by a bluff body in the stream, with no moving parts. They work on most steam, gas and liquid flows, so they are usually the first kind to compare for a steam line.

Positive displacement fuel meters

Oval gear, piston and similar meters trap fixed volumes and count them. They cope with viscous liquids and need little straight pipe, and are the usual family for diesel and fuel oil to generators and boilers.

Coriolis mass flow meters

Measure mass flow directly and report density too. One tube handles very different fluids without recalibration, so they suit chemical dosing, fuel and viscous products.

How to specify a flow meter

Liquid or gas
Say whether it conducts, carries solids or bubbles, or is viscous. Conductivity rules a magnetic meter in or out; bubbles upset transit-time ultrasonic readings.
Flow range and conditions
Minimum, normal and maximum flow, in m3/h for water, litres per hour for fuel or kg/h for steam, with pressure, temperature and, for fuel, viscosity.
Pipe and installation
Line size, pipe material and connection, and confirm the pipe runs full. Straight-run needs differ by kind and maker, so follow the quoted model's datasheet.
Accuracy basis
Ask whether accuracy is a percentage of reading or of full scale; two meters quoted at the same figure can differ at low flow.
Wetted materials
Liner and electrode material for a magnetic meter, or body material for a fuel meter, chosen so the parts in contact do not corrode.
Output and enclosure
A local totaliser, a pulse output for a logger or a signal to a PLC. IP67 covers immersion, not jets, so for monsoon pits ask for both, such as IPX5/IPX7.

Standards, tests and paperwork for flow meters

ISO 5167-1 and ISO 5167-2
Part 1 sets the general principles for pressure-differential flow devices in full circular pipes and Part 2 covers orifice plates. Ask for a plate made to the series, with its calculation sheet.
ISO 4064 and OIML R 49
The water meter standards. A meter is designated by its permanent flow Q3 in m3/h and the ratio Q3/Q1, for which OIML R 49 gives a standard list from 40 up to 1000.
BSTI verification schedule
The Weights and Measures Rules, amended in May 2024, list water meters, meters for liquids other than water and bulk or flow meters. For a billing meter, ask BSTI whether verification applies.
Calibration certificate
From an accredited laboratory, listing each flow point tested.

What moves the price of a flow meter

  • Principle: mechanical, electromagnetic, ultrasonic and Coriolis meters sit at different price levels for the same line.
  • Line size: a larger pipe raises the price of most kinds.
  • Materials: liners and electrodes for aggressive liquids, and hot-water builds, cost more.
  • Accuracy class: a tighter class usually costs more.
  • Extras: a remote transmitter, display, outputs and an accredited calibration certificate add to the bare meter.

Lead times and delivery

Lead times vary with the kind, the line size and whether a seller holds the meter in Bangladesh or brings it in to order. An imported meter adds build time, sea freight and clearance at Chattogram, and a local calibration certificate adds its own turnaround. Roptan confirms the dates and the minimum order in the quote.

We deliver anywhere in Bangladesh. A clamp-on ultrasonic meter goes on without cutting the pipe. For inline meters, the seller fits the meter, sets range and output, and commissions it with the pipe full. You receive the datasheet, calibration certificate, manual, warranty terms and a VAT invoice (Mushak 6.3).

What we check for this order

  • Principle against the liquidWe check the quoted kind suits your liquid: conductivity for a magnetic meter, clean liquid for transit-time, viscosity for fuel.
  • Datasheet matchWe check the meter against its datasheet for line size, liner, electrode or body material, flow range and output.
  • Calibration pointsWe check the certificate comes from an accredited laboratory and lists the flow points tested, not one accuracy figure.
  • Billing useFor a water or liquid meter that will bill someone, we ask the seller how the BSTI verification question is answered.

Questions buyers ask

Which flow meter suits generator diesel?

Usually a positive displacement meter, such as an oval gear meter: it counts fixed volumes, copes with viscous liquids and needs little straight pipe. A Coriolis meter also works. A magnetic meter will not, because diesel does not conduct. Send the line size and the flow range in litres per hour.

Can I measure flow without cutting the pipe?

Yes, with a clamp-on transit-time ultrasonic meter, which straps to the outside of the pipe. Its reading can be upset by bubbles, solids and temperature changes, so tell us the liquid, its temperature and how clean it is.

Which meter should I use on a steam line?

Vortex meters and orifice plates are the usual kinds to compare. A vortex meter has no moving parts. An orifice plate made to ISO 5167 is read through a differential-pressure transmitter, and the drop varies with the square of the flow. Give steam pressure, temperature, line size and flow range.

Does a water or fuel meter need BSTI verification?

BSTI's schedule lists water meters, meters for liquids and bulk or flow meters. If the meter bills a customer or tenant, ask BSTI whether verification applies before it goes in. For a meter that only monitors your own plant, keep a calibration certificate from an accredited laboratory.

How soon will I hear back about measuring instruments and meters?

Within 48 hours of a complete requirement, with a price and a delivery date. A requirement is complete when it has the model or specification, where it is needed and by when.

Who do I deal with?

With Roptan, when Roptan manages the order: we buy from the verified seller and deliver to you. With the supplier directly, when you post on the requirement board and choose a quote yourself.

Other measuring instrument products

Each product type has its own page as it is published; until then its card opens the category form.

All measuring instruments and meters