Managed sourcing from Bangladesh, for export and for buyers at home
Get it sourced

Electrical and electronics

Industrial automation supplier in Bangladesh

Send the motor list, the process and what must be controlled. As your industrial automation supplier in Bangladesh, we source drives, PLCs, HMIs, servo systems, soft starters and voltage regulators from verified sellers, check the models and deliver.

  • Verified sellers
  • Checked before it ships
  • Delivered by Roptan

Get industrial automation and drives sourced

Prefer to deal with suppliers yourself? Post it on the requirement board

Industrial automation products

Pick a product and we source it for you, or send one requirement that covers several.

Buying industrial automation and drives in Bangladesh

Garment, textile, food, pharmaceutical, cement and steel plants in Gazipur, Narayanganj, Savar, Chattogram and Dhaka fit drives on pumps, fans, compressors and conveyors, PLCs and HMIs to run machines and lines, and servo systems where motion must be precise. Many plants also fit voltage regulators or stabilisers, because supply voltage swings. A variable frequency drive is also sold as an inverter drive.

An industrial automation supplier in Bangladesh often quotes a drive by its kW rating and little else. Send us the motor nameplates, the duty and the panel conditions. We turn them into one specification, source from verified sellers, check models, ratings and test documents, and deliver to your plant. The seller or your panel builder installs and commissions. You deal with Roptan only.

Industrial automation and drives we source

Variable frequency drives

A drive, also called a VFD or inverter drive, varies motor speed by changing the supply frequency. On pumps and fans power falls steeply with speed, to about a quarter of full power at 63 percent speed, so the saving is largest there.

PLC controllers

A ruggedised industrial computer that reads sensors, runs a program and switches outputs, programmed in IEC 61131-3 languages such as ladder diagram. State digital and analogue I/O counts, spare points and the network it shares with HMIs and drives.

HMI panels

The touch screen operators use to start, stop, set and watch a machine. State screen size, the PLC it must talk to and over which protocol, the panel cut-out, and a front ingress rating for wet or dusty areas.

Servo drives and motors

A servo drive powers a servo motor and corrects it using a feedback sensor that reports actual position or speed. Used on cutting, packing, printing and winding machines where position matters. Buy drive, motor and cables as a matched set.

Soft starters

Direct-on-line starting draws about 7 to 10 times running current. A soft starter ramps the voltage to limit that inrush and to ease pump pressure surges and conveyor jerks. Choose it when the motor runs at one speed; choose a drive when speed must vary.

Automatic voltage regulators

The name covers two products: the regulator that holds a generator's output voltage at its set point, and mains stabilisers, servo or static, that correct supply voltage for machines. Say which you need, with kVA, phase, input range and load.

What to tell an industrial automation supplier in Bangladesh

Motor nameplate and load
Give kW, current, voltage and speed from the nameplate, and the load: a pump or fan, or a constant-torque load such as a conveyor or positive displacement pump, where speed control saves far less energy.
Supply
State three phase, 50 Hz, the voltage range measured at your board, and whether a generator feeds the plant, so drives, control power and stabilisers suit it.
Panel heat and humidity
Summer maxima usually reach 38 to 41 °C and July humidity 94 to 100 percent, and panels run hotter than room air. Drives lose rating above their stated ambient, so plan ventilation, filters or panel air-conditioning.
Harmonics and surges
A drive's input rectifier injects harmonic currents into the supply. On large drive loads, ask for line reactors or filters and surge protection, and say whether your utility or client sets a harmonic limit.
Program, licences and backup
Agree who writes the PLC and HMI programs, who owns the source files, and that a backup copy is handed over at commissioning.
Wireless modules
Gateways and HMIs with Wi-Fi, 4G or Bluetooth contain a radio, and the importer usually needs BTRC enlistment and a No Objection Certificate for each shipment. Wired versions avoid this.
Critical spares
Name the drives and controllers whose failure stops a line, and ask for spare units or boards.

Standards and paperwork for drives and controls

IEC 61800-5-1
Safety requirements, electrical, thermal, energy, fire and mechanical, for adjustable speed drive systems up to 1 kV AC. Ask for the certificate or test report for the drive frame and rating quoted.
IEC 61800-3
Electromagnetic compatibility of adjustable speed drive systems. Ask for the EMC test report and whether an input filter is included or needed near sensitive equipment.
IEC 61131-3
Programming languages for PLCs: ladder diagram, function block diagram, structured text and sequential function chart. Name a language your maintenance team can read and edit.
IEEE 519
A US standard for harmonic control that sets distortion limits at the point where a user's plant meets the supply. It is not a Bangladesh rule, but it can serve as a reference when sizing reactors and filters.
BTRC NOC and Mushak 6.3
For radio-equipped units, BTRC importer enlistment and a No Objection Certificate before each shipment, as importers describe the practice. For every order, a VAT invoice (Mushak 6.3).

What moves the price of drives and controls

  • Rating and duty: kW, overload capacity and whether the drive is sized for constant or variable torque loads.
  • Enclosure and cooling: ingress rating, a ventilated or air-conditioned panel, and a larger frame where heat forces derating.
  • Harmonic and EMC parts: line reactors, input filters and output reactors add cost but protect the supply and motor.
  • Control features: built-in PLC functions, safety inputs, communication cards and encoder feedback.
  • Programming and commissioning: PLC and HMI programs, servo tuning and site testing are often priced separately.
  • Spares and warranty: spare units or boards, replacement terms and repair support after handover.

Lead times and delivery

Common drive sizes, soft starters, small PLCs and stabilisers are often held in stock in Dhaka. Large drives, servo sets, specific PLC models and panels built to order may be imported or assembled to order, customs clearance adds time, and radio-equipped units can wait on BTRC papers. Roptan confirms dates and any minimum quantity for each order in the quote.

We deliver to plants across Bangladesh, from Gazipur, Savar and Narayanganj to Chattogram and Mirsarai. The seller or your panel builder installs, sets drive parameters, loads and tests the PLC and HMI programs, and commissions with your team. You receive the parameter list, program backups and source files as agreed, wiring drawings, the warranty and a VAT invoice (Mushak 6.3).

What we check for this order

  • Trade licence, and BSTI where requiredCurrent, in the name on the quote, with any BSTI requirement for the item confirmed before the order is placed.
  • Type test reports for the model quotedIEC 61800-5-1 safety and EMC reports from the factory lab or an accredited third party, for the drive frame and rating quoted.
  • Warranty and after sales in writingRepair or replacement terms, spare boards and fans, and who supports the programs after handover, included or priced.
  • A visit to the assembly lineBefore a panel or stabiliser order, we see the assembly line and test bench, and check parts, ventilation and wiring against the drawings.

Questions buyers ask

Is a VFD the same as an inverter?

Not always. A variable frequency drive is also known as an inverter drive. On its own, the word inverter also covers battery and solar inverters and IPS units, which are different products and not what a motor needs. Tell us the motor and what it drives, so the quote is for a drive.

Will a drive save energy on our pump or fan?

Usually, if flow or air volume varies. On pumps and fans power falls roughly with the cube of speed, so at 63 percent speed the motor draws about 25 percent of full power. On conveyors and other constant-torque loads the saving is much smaller.

Should we fit a soft starter or a drive?

A soft starter limits starting current, which on direct-on-line starting is about 7 to 10 times running current, and eases pressure surges and belt jerks. It does not control speed. Choose a drive when speed must vary or energy saving matters, and a soft starter when the motor runs at one speed.

What does AVR mean in a quote?

It can mean two things. A generator's automatic voltage regulator holds the alternator output at its set point. A mains voltage stabiliser, servo or static type, corrects the supply to machines. State which you need, with kVA, phase, input voltage range and the load, so quotes compare like for like.

Do drives need special care in Bangladeshi heat?

Yes. Drive ratings assume an ambient limit stated on the datasheet; above it, drives are derated, roughly 1 percent per degree Celsius, or need forced cooling. Humid air can also condense on cool boards. Plan ventilation, filters or panel air-conditioning, and ask for coated boards.

How soon will I hear back about industrial automation and drives?

Within 48 hours of a complete requirement, with a price and a delivery date. A requirement is complete when it has the quantity, where it is needed and by when.

Who do I deal with?

With Roptan, when Roptan manages the order: we buy from the verified seller and deliver to you. With the supplier directly, when you post on the requirement board and choose a quote yourself.