Managed sourcing from Bangladesh, for export and for buyers at home
Get it sourced

HVAC and cold chain · Cooling towers

Closed circuit cooler supplier in Bangladesh

Roptan is a closed circuit cooler supplier in Bangladesh for process loops, chiller and heat pump circuits. Send the fluid, its flow and temperatures and the site, and we source a wet, hybrid or adiabatic cooler from a verified seller, check it and deliver.

  • Verified sellers
  • Checked before it ships
  • Delivered by Roptan

Get closed circuit coolers sourced

Prefer to deal with suppliers yourself? Post it on the requirement board

Buying closed circuit coolers in Bangladesh

A closed circuit cooler, also called a fluid cooler, runs the process fluid through a coil inside the unit while spray water and air cool the outside of the coil. The fluid never meets the air, so it stays protected from dirt and contamination. Factories, chiller plants and heat pump loops that need a closed loop buy them. A closed circuit cooler supplier in Bangladesh should select it for your fluid, not plain water by default.

Roptan has each verified seller state the fluid, its flow and temperatures and the design wet bulb, then checks which rating or field test applies, how the spray water will be treated and what papers come with the unit. The seller sets and commissions the cooler on your loop.

Kinds of closed circuit cooler

Induced draft closed circuit coolers

The fan sits at the outlet and draws air over the wetted coil, in crossflow, counterflow or mixed flow layouts. Choose it for wet duty on process and chiller loops.

Forced draft closed circuit coolers

The fan pushes air in at the base. Exhaust leaves slower, so warm air returning to the inlet is a greater concern; leave open space around it.

Hybrid wet-dry coolers

Switch between wet and dry running. Choose them when you want to save spray water in cooler months and run wet in the hot season.

Adiabatic coolers

Pre-cool the incoming air with water but keep the coil dry. Choose them where spray water must be cut back and the fluid can stay further from the wet bulb than a wet unit would bring it.

Dry coolers

Cool the fluid through the coil by air alone, with no evaporation. Choose them where water is scarce and the fluid can run warmer than a wet cooler would deliver.

How to specify a closed circuit cooler

Process fluid
Water or a water-glycol mix, with the mix ratio. The seller states the fluid and its properties on the selection, since glycol changes the duty.
Flow and temperatures
The fluid's flow in m³ per hour, its inlet and outlet temperatures and the design wet bulb from your consultant.
Single phase duty
Say whether the fluid stays liquid through the coil. A condensing duty is a different product, the evaporative condenser.
Spray water analysis
The spray side still evaporates, so its dissolved solids concentrate and can scale the coil. Send hardness, TDS and iron for the make-up.
Make-up supply
In Dhaka about 87 percent of water demand came from groundwater in 2021. Confirm the make-up source and ask the seller for blowdown at your duty.
Drift
Spray water leaves as mist. Ask for the drift eliminator and its drift figure as a percentage of spray flow.

Ratings and tests a closed circuit cooler supplier in Bangladesh should name

CTI STD-201
The Cooling Technology Institute's certification of published thermal ratings, which covers closed circuit coolers as well as open towers. Ask whether the model is on the certified list.
CTI ATC-105S
The field test code for closed circuit towers, limited to sensible cooling of single phase fluids such as water or water-glycol whose properties are agreed before the test.
Eurovent certification
A European programme for checked thermal ratings, run in cooperation with CTI. A certified rating from either route is checkable.
ANSI/ASHRAE Standard 188-2021
Minimum Legionella risk management for building water systems. The spray circuit is open water, so ask for a water management plan.

What moves the price of a closed circuit cooler

  • Duty and approach: fluid flow and how close the outlet must come to the wet bulb.
  • Running mode: wet, hybrid, adiabatic or dry, and the controls to switch.
  • Fluid: water-glycol changes the selection against plain water.
  • Fan arrangement: induced or forced draft and the airflow layout.
  • Proof of rating: a certified model, or a field test to ATC-105S.
  • Spray water care: drift eliminators, filtration and dosing.

Lead times and delivery

No fixed lead time can be given for closed circuit coolers. A catalogue model in a running size is usually the quicker route. Units selected for water-glycol, hybrid or adiabatic controls, imported units cleared at Chattogram, a field test and a roof lift add time. Roptan confirms the dates and the minimum order in the quote.

Roptan delivers the cooler to your site anywhere in Bangladesh. The seller sets it level, connects the process loop and spray water, fills the process circuit and checks it for leaks, aligns the fan and records a test run with fluid flow, temperatures and fan current. Handover includes drawings, the selection for your fluid, the O&M manual, the water treatment plan, the warranty and a VAT invoice (Mushak 6.3).

What we check for this order

  • Fluid on the selectionWe check the selection names your fluid and mix, not plain water, at your flow and temperatures.
  • Wet bulb basisWe check the duty is stated at your design wet bulb, so offers can be compared.
  • Rating routeWe check whether the model is on a certified list or, if not, that a field test to ATC-105S is written in.
  • Spray water planWe ask for the treatment and drift figures for the spray side before the order is placed.

Questions buyers ask

Closed circuit cooler or open tower with a heat exchanger?

Both keep the process loop clean. A closed circuit cooler does it in one unit with the coil inside the tower. An open tower with a plate heat exchanger splits the job into two pieces of plant. Send the duty and we ask verified sellers to quote both at the same conditions.

Can a closed circuit cooler handle water-glycol?

Yes. CTI's field code for closed circuit towers names water-glycol among the single phase fluids it covers, provided the fluid properties are agreed before the test. Give the mix ratio, since the seller's selection depends on it.

Does a closed circuit cooler still need water treatment?

Yes, on the spray side. That water evaporates, so its dissolved solids concentrate and can scale the outside of the coil, and open water can carry Legionella. Ask for a treatment plan with bleed-off, dosing and cleaning, set from your make-up water analysis.

Is a dry cooler enough in Bangladesh?

Only if the fluid can run warm. A dry cooler uses no evaporation and cools by air alone, while summer maxima run around 38 to 41 °C. Where the fluid must come close to the wet bulb, a wet or hybrid unit is usually needed.

How soon will I hear back about cooling towers?

Within 48 hours of a complete requirement, with a price and a delivery date. A requirement is complete when it has the capacity, where it is needed and by when.

Who do I deal with?

With Roptan, when Roptan manages the order: we buy from the verified seller and deliver to you. With the supplier directly, when you post on the requirement board and choose a quote yourself.

Other cooling tower products

Each product type has its own page as it is published; until then its card opens the category form.

All cooling towers