Managed sourcing from Bangladesh, for export and for buyers at home
Get it sourced

Machinery and handling · Boilers

Thermic fluid heater supplier in Bangladesh

Roptan is your thermic fluid heater supplier in Bangladesh for gas and oil fired heaters. Tell us the heat load, oil temperature and fuel: we source from verified sellers, check the heater, its fluid data and papers, and deliver to site.

  • Verified sellers
  • Checked before it ships
  • Delivered by Roptan

Get thermic fluid heaters sourced

Prefer to deal with suppliers yourself? Post it on the requirement board

Buying thermic fluid heaters in Bangladesh

A thermic fluid heater burns gas or oil to heat an organic heat transfer oil, which a pump circulates to the machines that need dry heat. The oil has a lower vapour pressure than water, so it reaches high temperatures, usually up to about 300 °C, at low pressure. Textile mills audit these heaters separately from their steam boilers, with routine analysis of the oil.

A thermic fluid heater supplier in Bangladesh should be clear on two things: the fluid's limits, and whether the heater falls under the Boiler Act. Roptan sources from verified sellers, checks the heater, its fluid data and its papers, and delivers; the seller erects and commissions it. You deal with Roptan only.

Kinds of thermic fluid heater

Gas fired thermic fluid heaters

A forced draught gas burner built to EN 676 fires the heater. Choose it where you have a gas connection approved for the extra load; mills count the heater as its own gas user beside the boiler.

Oil fired thermic fluid heaters

A burner built to EN 267 on diesel or furnace oil. Furnace oil must be heated, usually to roughly 65 to 120 °C, and filtered before it atomises, and its sulphur can corrode a heater left to cool.

Heaters with a steam generator

Some packages raise steam from the hot oil in an attached generator. Treat that water-side vessel as a boiler component and plan its registration with the Chief Inspector.

Mineral and synthetic fluid systems

Heat transfer oils come as oil-based and synthetic fluids, both with lower vapour pressure than water. The fluid's rated maximum temperature, from its data sheet, limits the whole system.

How to brief a thermic fluid heater supplier in Bangladesh

Heat output
In kW or kcal/h for each machine on the circuit, at peak and average, with the hours run each day.
Oil temperature
The temperature each machine needs, usually no more than about 300 °C; organic fluids start to decompose at the top of their range.
Fluid
Mineral or synthetic, with its data sheet and rated maximum temperature, and who supplies the first charge and the top-ups.
Fuel and burner
Gas with your connection status, or oil with its grade. Gas burners are built to EN 676, oil burners to EN 267.
Fluid analysis
Ask how often the seller recommends sampling the oil, and who tests it. Mills treat thermic fluid oil analysis as routine.
Efficiency
Ask which method the figure comes from and on which calorific value; on natural gas, net reads several points above gross.
Pump and expansion
Flow in cubic metres per hour and head in metres for the whole circuit, a standby pump where a stop costs production, and an expansion tank sized to the fluid volume, since hot oil expands.
Electrical supply
Three phase 50 Hz for burner, pump and panel; say whether the heater must restart on generator power after a mains cut.

Safety standards and registration

DIN 4754
Heat transfer installations with organic fluids: part 1 safety requirements and testing, part 2 the draught diverter, part 3 the level controller. Ask whether the heater is built to it.
EN 676 and EN 267
Forced draught burners for gaseous and liquid fuels respectively. Ask which applies and for the burner's rated range.
Boiler Act 2022
The Act defines a boiler as a vessel making steam from water, so a closed oil circuit is not clearly covered. Confirm with the Chief Inspector whether your unit must be registered.
Fluid data sheet and SDS
The fluid's data sheet with its rated bulk and film temperatures and flash point, and a safety data sheet to GHS, kept with the heater's papers.

What moves the price of a thermic fluid heater

  • Output and temperature: more heat and a hotter oil need a larger heater and a fluid rated for it.
  • Fluid: the first charge, and its replacement once analysis shows it has broken down.
  • Fuel side: furnace oil adds heating and filtering; gas needs an approved connection and burner.
  • Steam generator: an attached steam-raising vessel adds cost and registration work.
  • Safety devices: a level controller and draught diverter of the kinds DIN 4754 covers.

Lead times and delivery

Dates depend on whether the heater is built here or imported, on the fuel side and on the papers. If the heater or its steam generator is to be registered, approvals come first. Whether the Chief Inspector's prior import approval covers these heaters is not clear, so the seller confirms before shipment. A gas fired heater also waits on its connection. Roptan confirms dates and any minimum in the quote.

We deliver to your site. The seller sets the heater, pipes it to your machines, fills and circulates the fluid, commissions burner and controls and trains your operator. Papers at handover: drawings, the fluid data sheet, burner and safety device documents, the commissioning record, the seller's written answer on registration, and a VAT invoice (Mushak 6.3).

What we check for this order

  • Fluid data sheetWe check that the fluid's rated maximum temperature covers the oil temperature you need, with the seller's margin stated.
  • DIN 4754 safety devicesWe ask whether the heater is built to DIN 4754, with its level controller and draught diverter listed in the quote.
  • Registration answerBefore ordering, we ask the seller in writing whether the heater or its steam generator is to be registered; you confirm with the Chief Inspector.
  • Burner standardWe check the burner is built to EN 676 or EN 267 and rated for the heater's output.

Questions buyers ask

Does a thermic fluid heater need registration in Bangladesh?

It is not settled, so confirm with the Chief Inspector whether your unit must be registered. The Boiler Act 2022 defines a boiler as a closed vessel of more than 25 litres used to make steam from water, and a closed oil circuit makes no steam. A steam generator attached to the heater is another matter: treat it as a boiler component.

Thermic fluid heater or steam boiler?

Choose by temperature and process. A thermic fluid heater reaches high temperatures, usually up to about 300 °C, at low pressure, because the oil's vapour pressure is lower than water's. Textile mills put most of their heat into dyeing and finishing, often run both, and audit them as separate systems. Tell us each machine's heat need.

Why does the oil need analysis?

Organic heat transfer fluids start to decompose at the top of their temperature range, so their condition changes with use. Mills treat thermic fluid oil analysis as a routine item. Ask the seller for a sampling plan and the point at which the fluid should be replaced.

Can I run a thermic fluid heater on gas?

Where you can get gas. Heaters follow the same industrial gas rules as boilers: new connections outside economic zones and industrial parks were stopped from April 2021 and, as reported, resumed in April 2025 with priority to export-oriented factories. Check your connection and approved load first; otherwise an oil burner built to EN 267 can fire the heater.

How soon will I hear back about boilers?

Within 48 hours of a complete requirement, with a price and a delivery date. A requirement is complete when it has the model or specification, where it is needed and by when.

Who do I deal with?

With Roptan, when Roptan manages the order: we buy from the verified seller and deliver to you. With the supplier directly, when you post on the requirement board and choose a quote yourself.

Other boiler products

Each product type has its own page as it is published; until then its card opens the category form.

All boilers