Managed sourcing from Bangladesh, for export and for buyers at home
Get it sourced

HVAC and cold chain · Dehumidifiers

Industrial dehumidifier supplier in Bangladesh

Roptan acts as your industrial dehumidifier supplier in Bangladesh. Send the room, its temperature and the humidity to hold: we source heavy refrigerant units from verified sellers, check ratings and coatings against your conditions, and deliver to site.

  • Verified sellers
  • Checked before it ships
  • Delivered by Roptan

Get industrial dehumidifiers sourced

Prefer to deal with suppliers yourself? Post it on the requirement board

Buying industrial dehumidifiers in Bangladesh

An industrial dehumidifier is a large refrigerant unit for manufacturing plants, commercial buildings and storage warehouses. A cold coil condenses water out of the air and the condenser coil reheats it. These units suit warm, humid rooms with a high moisture load, which describes most production rooms in Bangladesh in the June to September monsoon.

The unit you choose has to suit the room's temperature, its dust and the air around it, not only its size. As your industrial dehumidifier supplier in Bangladesh, Roptan sends one brief to verified sellers, asks each to rate the unit at a stated condition, checks the safety report and the coil coating, and delivers.

Kinds of industrial dehumidifier

Standard refrigerant units

The usual choice for moderate conditions, such as about 50 percent RH in a room above 10 °C, where they are low in cost. Choose them for warm production rooms and stores.

Refrigerant units with defrost

Fitted with a frost sensor that starts a defrost cycle so the coil clears when it ices. Choose them for rooms that run cool, after the temperature and target are known.

Units with coated coils and casings

Coil and casing protection chosen for a stated corrosivity category. Choose them near the coast or in chemical or chlorinated air.

Enclosed and filtered units

An electrical enclosure with a stated IP rating and a classified air filter. Choose them for dusty or wet production rooms.

Desiccant units instead

When the target is below about 35 percent RH or the room is cool, a refrigerant unit is the wrong tool. Desiccant units are used in industry to reach those levels.

How to specify an industrial dehumidifier

Room temperature and target
Refrigerant units typically work well at 20 °C and above with humidity of about 50 percent or more. State both so the seller can check the fit.
Intake dew point
If the incoming air's dew point is below about 10 °C, the coil runs below freezing, ice blocks airflow and defrost cycles stop drying. Mainly a cool-room issue.
Humidity limit
The US EPA advises indoor relative humidity below 60 percent, ideally 30 to 50 percent, for mould control. Your process or product may set a tighter figure.
Supply
Large units usually run on three phase at 50 Hz, nominally 380 to 400 V. Check the data plate against the supply.
Corrosion category
Ask the seller to state the atmosphere the coating was chosen for, as an ISO 9223 corrosivity category or an ISO 12944-2 environment class.
Enclosure and filters
For dust or water, ask for the IP code to IEC 60529 and the filter class to ISO 16890-1.
Controls
For units with variable-speed fans or electronic controls, ask whether they were tested for industrial EMC immunity to EN IEC 61000-6-2:2019.

Ratings, safety and the paperwork to ask for

Stated rating condition
Capacity compares only at one condition. US tests use 65 °F (18.3 °C) and 60 percent RH; many makers in Asia quote 30 °C and 80 percent, which reads larger.
EN 810
The European standard for compressor dehumidifiers: rating tests, marking and a technical data sheet. Ask which edition the data sheet follows.
Safety test report
IEC 60335-2-40 covers dehumidifier safety, but its title says household and similar appliances. For a large unit, ask which safety standard the test report cites.
EN 378-1:2016+A1:2021
Safety and classification rules for refrigerating systems and heat pumps, relevant to larger units and to models with flammable refrigerants.
EN 12102-1:2022
How sound power of compressor dehumidifiers is determined. The 2017 edition was withdrawn in 2022, so ask for a figure to the current one.

What moves the price of an industrial dehumidifier

  • Conditions: a moderate target keeps you on a refrigerant unit; a low target or cool room means desiccant, which usually costs more to buy.
  • Real output: icing and defrost cut effective capacity, so a unit sized from the label may be too small.
  • Coatings for a higher corrosivity category, on the coil, casing and fixings.
  • Enclosure rating, filter class and three phase electrical work.

Lead times and delivery

No typical lead time is given here. These machines are usually imported. A unit in a seller's stock arrives sooner; one with special coatings, enclosures or controls waits for the maker, shipping and clearance at Chattogram. Drain and three phase work on site add time. Roptan confirms the dates and any minimum in the quote.

We deliver to site anywhere in Bangladesh. The seller places the unit, connects power and the drain, and commissions it, with room humidity read before and after on a calibrated instrument. Handover includes the data sheet, safety test report, manuals, warranty papers and a VAT invoice (Mushak 6.3).

What we check for this order

  • Capacity at your conditionWe ask every seller for capacity and power at one stated temperature and humidity, close to your room's, so offers compare fairly.
  • Safety standard namedWe ask which standard the safety test report cites, rather than accept a claim that IEC 60335-2-40 covers a large unit.
  • Plate against the orderWe compare the data plate and the EN 810 data sheet with the order: model, capacity with its condition, refrigerant, voltage and 50 Hz.
  • Calibrated readingsWe ask for humidity readings before and after commissioning on instruments calibrated by an ISO/IEC 17025 accredited lab.

Questions buyers ask

Refrigerant or desiccant for a production room?

Refrigerant, in most warm Bangladesh rooms: it suits warm, humid air with a high moisture load and costs less in moderate conditions. Choose desiccant for targets below about 35 percent RH or cool rooms, where refrigerant coils freeze.

Why does an industrial unit ice up?

When the incoming air's dew point is below about 10 °C, the coil runs below freezing. Ice blocks airflow and the unit stops drying while it defrosts. It happens in cool rooms, not in a typical warm production room.

Does IEC 60335-2-40 cover a large industrial unit?

Not certainly. Its title covers household and similar appliances, so whether it applies to a large machine depends on the unit. Ask the seller for the test report and the standard it cites, and check it names the exact model.

Which customs code do dehumidifiers come under?

No six-digit HS subheading is named for dehumidifiers. Customs rulings in the United States have placed them under headings 8415, 8479 and 8509, depending on the unit, and duty follows the heading. Ask the importing seller and the customs broker to agree the code in writing before shipment, and keep it on the quote.

How soon will I hear back about dehumidifiers?

Within 48 hours of a complete requirement, with a price and a delivery date. A requirement is complete when it has the capacity, where it is needed and by when.

Who do I deal with?

With Roptan, when Roptan manages the order: we buy from the verified seller and deliver to you. With the supplier directly, when you post on the requirement board and choose a quote yourself.

Other dehumidifier products

Each product type has its own page as it is published; until then its card opens the category form.

All dehumidifiers