Managed sourcing from Bangladesh, for export and for buyers at home
Get it sourced

HVAC and cold chain · Dehumidifiers

Ceiling mounted unit supplier in Bangladesh

Roptan is your ceiling mounted unit supplier in Bangladesh for dehumidifiers that hang above the ceiling. Tell us the room, the ceiling void, the humidity to hold and where water can drain: we source from verified sellers, check the details and deliver.

  • Verified sellers
  • Checked before it ships
  • Delivered by Roptan

Get ceiling mounted units sourced

Prefer to deal with suppliers yourself? Post it on the requirement board

Buying ceiling mounted units in Bangladesh

A ceiling mounted unit is a compact refrigerant dehumidifier hung from the structure above a false ceiling, or set in a nearby plant space. It takes air from the room or from a return duct and sends dried air back through ducts. It suits offices, archives, labs and shops where floor space is short or a unit on the floor would be in the way.

Out of sight also means out of reach, so the details that matter are the drain, the supports and the service access. As your ceiling mounted unit supplier in Bangladesh, Roptan sources the unit from a verified seller, checks those details against the model's own manual and delivers it for the seller to install.

Kinds of ceiling mounted dehumidifier

Units above a false ceiling

Hung on threaded rod and support channels from the slab, with ducts down to the room. Choose one where the ceiling void is deep enough and an access panel can sit beside it.

Units in a plant space

The same compact unit set in a service room or void next to the space, ducted through the wall or ceiling. Choose it when the ceiling void cannot take the unit.

Room-air inlet units

The inlet draws air straight from the room, often through a short insulated flexible duct that also cuts fan noise.

Return-duct units

The inlet connects to an existing HVAC return duct, so the dehumidifier works alongside the air conditioning. Ask whether the quoted model supports this layout.

How to specify a ceiling mounted unit

Supports
Ask for the operating weight and check the rods and channels can carry it. Specify vibration isolators between the channels and the unit base.
Filter access
Ask for the clearance the model's manual requires on the filter side, keep the rods clear of the filter doors, and place a ceiling access panel at that side.
Condensate
If no drain is near, a condensate pump may be needed. The drain pan should slope to the drain and the drain must flow freely, since standing water breeds mould.
Noise
Insulated flexible duct on the inlet and vibration isolators reduce fan noise. Ask for the sound level the room will hear.
Operating range
The model's data sheet states an inlet air temperature and humidity range. Check it against the room, including an air-conditioned room on a cool night.
Target and capacity
The US EPA advises indoor humidity below 60 percent, ideally 30 to 50 percent. Ask for capacity with the temperature and humidity it was rated at.
Supply
Check the voltage and 50 Hz frequency on the data plate against the supply at the ceiling.

Ratings, safety and noise data to ask for

Stated rating condition
US tests rate at 65 °F (18.3 °C) and 60 percent RH; many makers in Asia quote 30 °C and 80 percent, which reads larger. Compare offers on one condition.
IEC 60335-2-40 with IEC 60335-1
The electrical safety standard for dehumidifiers. Ask for the test report or certificate for the exact model.
ISO 16890-1 and IEC 60529
Filter class for the ducted air, and the IP code of the housing if it faces dust or splash. Ask for a filter cleaning interval too.
EN 12102-1:2022
How the sound power of compressor dehumidifiers is determined. The 2017 edition was withdrawn in 2022, so ask for a figure to the current one.

What moves the price of a ceiling mounted unit

  • Capacity at your room's conditions, compared on one rating condition.
  • Ducting on the inlet and supply, including insulated flexible duct.
  • A condensate pump where no drain is near the unit.
  • Supports, vibration isolators and the ceiling access panel.

Lead times and delivery

No typical lead time is given here. A model in a seller's stock arrives sooner than one imported to order, which waits for shipping and customs clearance. On site, time depends on access to the ceiling void, the drain or pump route, the ducting and coordination with the ceiling contractor. Roptan confirms the dates and any minimum in the quote.

We deliver to site anywhere in Bangladesh. The seller hangs the unit from the structure on isolators, connects ducts, drain or pump and power, and commissions it. Before the ceiling is closed, the drain is shown flowing freely and the filter is reached through the access panel. Handover includes the manual, warranty papers and a VAT invoice (Mushak 6.3).

What we check for this order

  • Drain or pumpWe confirm where the water goes before the order: a gravity drain with a free fall, or a condensate pump.
  • Access to the filterWe check the access panel sits on the filter side and that no support rod blocks the filter doors.
  • Operating rangeWe compare the model's stated inlet air range with your room's temperature and humidity, day and night.
  • Calibrated readingsWe ask for room humidity before and after on an instrument calibrated by an ISO/IEC 17025 accredited lab.

Questions buyers ask

What if there is no drain near the ceiling?

Then a condensate pump is usually needed to lift the water to a drain. Agree the pump and its pipe route before the ceiling is closed, and have the drain shown flowing freely, since standing water in a drain pan breeds mould.

Will a ceiling dehumidifier be noisy?

Some fan noise reaches the room. Vibration isolators under the unit and a short run of insulated flexible duct on the inlet reduce it. Ask the seller for the sound power level, measured to EN 12102-1:2022.

How is the filter cleaned?

Through a ceiling access panel on the filter side. The model's manual gives the clearance needed to slide the filter out; rods and ducts must not block it. Ask for the filter class and the cleaning interval.

Does a ceiling unit work in an air-conditioned room?

It depends on the model. Its data sheet states an inlet air range, and some fit a frost sensor that stops the unit when the coil gets too cold. Give the seller the room's lowest temperature and check it against that range.

How soon will I hear back about dehumidifiers?

Within 48 hours of a complete requirement, with a price and a delivery date. A requirement is complete when it has the capacity, where it is needed and by when.

Who do I deal with?

With Roptan, when Roptan manages the order: we buy from the verified seller and deliver to you. With the supplier directly, when you post on the requirement board and choose a quote yourself.

Other dehumidifier products

Each product type has its own page as it is published; until then its card opens the category form.

All dehumidifiers