Managed sourcing from Bangladesh, for export and for buyers at home
Get it sourced

Electrical and electronics · Cables and wires

House wiring cable manufacturer in Bangladesh

Need a house wiring cable manufacturer in Bangladesh? Send the sizes, solid or stranded, insulation, colours and coil count. We source from verified makers, check the BSTI licence, measure conductor resistance on samples from your lot and deliver to site.

  • Verified sellers
  • Checked before it ships
  • Delivered by Roptan

Get house wiring cables sourced

Prefer to deal with suppliers yourself? Post it on the requirement board

Buying house wiring cables in Bangladesh

House wiring cable is the single-core, PVC-insulated wire pulled through conduit to every light point, socket and distribution board in a building, rated up to 450/750 V. Contractors, developers and building owners buy it by the coil. More than 120 firms make cable and wire in Bangladesh, and trade members have named counterfeit goods and poor raw material as the sector's main problems.

Once wire is plastered into a wall, nobody looks at it again. So Roptan takes your order to a verified house wiring cable manufacturer in Bangladesh, confirms the BSTI licence covers the construction, has samples from your coils measured and delivers with the papers. You deal with one contact, or post the need on our requirement board.

Kinds of house wiring cable

Solid single-core wire

One solid copper conductor under PVC insulation, common in the small sizes in many markets. Choose it for lighting and socket circuits with short, straight conduit runs.

Stranded single-core wire

Copper strands twisted into one conductor, so the wire bends and pulls through conduit more easily. Sizes above about 5 mm² are usually stranded. Choose it for larger circuits and runs with many bends.

Low smoke zero halogen (LSZH) wire

A halogen-free compound that gives less dense smoke and cuts toxic, corrosive gas when it burns. Choose it for enclosed spaces people may have to leave through smoke.

How to brief a house wiring cable manufacturer in Bangladesh

Standard and edition
Name IEC 60227-1:2024 or BDS 900:2010. A quote citing the 2007 edition of IEC 60227-1 names a text withdrawn in February 2024.
Size in mm²
Give the nominal cross-section per circuit. IEC 60228 sets the resistance each size must meet, so size is something you can test.
Conductor metal
Ask for plain copper in writing. Aluminium wire on fittings made for copper was found to cause faulty joints and fire risks in North America in the 1960s and 1970s.
Supply and rating
Wire to IEC 60227 is specified for AC installations up to 450/750 V, enough for a 50 Hz building supply, single and three phase. DC solar strings sit outside that scope, so ask for solar cable there.
How it is installed
Say how many circuits share each conduit and whether runs cross roof spaces. Grouped and enclosed cables carry less current; IEC 60364-5-52 sizes cable by installation method.
Heat and damp
Bangladesh is hot and humid for much of the year, and wire in roof voids or damp walls sees both. State the insulation temperature rating you need.

Standards and papers for house wiring cable

IEC 60227-1:2024
General rules for PVC-insulated cables up to 450/750 V, edition 4.0, calling up test methods in IEC 63294, IEC 60332-1-2 and the IEC 60811 series.
BDS 900:2010 and the BSTI mark
BSTI lists non-armoured PVC insulated cables for power and lighting to BDS 900:2010 under mandatory certification marks. Ask for the licence and check that it covers the construction quoted.
IEC 60228:2023
Sets nominal sizes from 0.5 to 3,500 mm² and the resistance limit for each. Its European version, EN IEC 60228:2024, replaced EN 60228:2005.
IEC 60332-1-2:2025
The vertical flame test on one insulated wire with a 1 kW flame. It shows whether fire travels along the wire, not how much smoke it makes.
IEC 60754-1 and IEC 61034-2
Tests for halogen acid gas and smoke density. An LSZH wire should come with a report for each, or the label is only a claim.

What moves the price of house wiring cable

  • Copper: raw materials are usually 70 to 80 percent of a local maker's cost, so quotes move with the metal price.
  • Size: each step up in cross-section puts more copper into every metre, so a larger conductor costs more per coil.
  • Recycled copper and thin insulation: one 2026 analysis put this informal segment at about 10 to 12 percent of the market.
  • Testing: a resistance test on your samples or an outside lab report adds a cost untested wire does not carry.

Lead times and delivery

Common PVC sizes held in stock usually leave sooner than LSZH wire or unusual sizes run to order. A licence check, a resistance test on samples and a long mixed schedule each add time, and a sharp copper move can reopen the price. Roptan confirms dates and any minimum per size in the quote.

Roptan delivers coils to sites, stores and contractors' yards across Bangladesh, kept dry in transit, with a packing list by size and colour, the test records for the lot, a copy of the BSTI licence and a VAT invoice (Mushak 6.3). Wiring the building stays with your electrician or contractor.

What we check for this order

  • BSTI licence for this constructionWe check the licence number and scope against BDS 900:2010 and the exact cable quoted, not just the logo.
  • Conductor resistance on your coilsSamples cut from your coils are measured against the IEC 60228 limit for the size; thin copper or copper-clad aluminium fails.
  • Conductor metal and strandsWe strip a sample to confirm solid copper, not a copper skin over aluminium, and count the strands.
  • Test records and editionRecords must name IEC 60227-1:2024 or BDS 900:2010 and include the flame test; LSZH wire adds gas and smoke reports.

Questions buyers ask

Does house wiring cable need a BSTI mark?

For the common PVC types, yes: BSTI lists non-armoured PVC insulated cables for power and lighting to BDS 900:2010 under mandatory certification marks. The list keeps growing, counting 328 products in July 2026, so we confirm with BSTI that the licence covers your construction.

Should I buy solid or stranded wire?

Solid is common in the small sizes; stranded from about 5 mm² up and for runs with many bends, because it pulls through conduit more easily. IEC 60227 covers both, and one order can mix them by size.

Which edition of IEC 60227 should the quote name?

IEC 60227-1:2024, edition 4.0, published on 22 February 2024. The 2007 edition was withdrawn that day, so a quote or test report citing it is out of date. A Bangladeshi maker may quote BDS 900:2010, the standard on BSTI's list.

How do I know the wire has the copper it claims?

Measure it. Conductor resistance must stay within the IEC 60228 limit for the size. Copper-clad aluminium, an aluminium core with a thin copper skin, fails, and so does an undersized conductor. We test samples from your coils before you pay.

How soon will I hear back about cables and wires?

Within 48 hours of a complete requirement, with a price and a delivery date. A requirement is complete when it has the quantity, where it is needed and by when.

Who do I deal with?

With Roptan, when Roptan manages the order: we buy from the verified seller and deliver to you. With the supplier directly, when you post on the requirement board and choose a quote yourself.

Other cable products

Each product type has its own page as it is published; until then its card opens the category form.

All cables and wires