Managed sourcing from Bangladesh, for export and for buyers at home
Get it sourced

Machinery and handling · Valves

Check valve supplier in Bangladesh

Roptan is your check valve supplier in Bangladesh for pump outlets, water mains and process lines. Send the size, rating, design and service: we source from a verified importer or stockist, check the test record and markings, and deliver.

  • Verified sellers
  • Checked before it ships
  • Delivered by Roptan

Get check valves sourced

Prefer to deal with suppliers yourself? Post it on the requirement board

Buying check valves in Bangladesh

A check valve, also called a non-return valve, lets fluid pass one way and closes when the flow tries to reverse. Flow opens it; gravity, a spring or the reverse pressure closes it. In Bangladesh it is bought for pump outlets in building and factory water systems, fire lines, boiler feed lines and process pipework.

A check valve supplier in Bangladesh should tell you how the valve closes, the pressure that opens it and the standard it is tested to. Tell Roptan the line and the pump: we source from verified sellers, compare like for like, check the papers and markings, and deliver to site.

Kinds of check valve

Swing check valves

A disc on a hinge swings open with the flow. Common on larger water and process lines; water hammer is a common problem with swing checks, as the disc slams shut when flow stops abruptly.

Lift and in-line check valves

Inlet pressure lifts a guided disc off its seat; gravity or downstream pressure reseats it. In-line checks add a spring, and ball checks close with a ball. Ask for the opening pressure.

Wafer check valves

A flangeless body fitted between two pipe flanges, or against one, and held by their through-bolts. Confirm the face-to-face dimension and the rating at your temperature.

Non-slam check valves

Built to close without relying on the flow, so the disc seats before reverse flow builds up. Choose one on pump outlets, where a slam at every stop damages pumps and pipes.

Stop-check valves

A check valve with an override that closes it whatever the flow direction or pressure. Choose it where one valve must both stop backflow and shut the line on command.

How to brief a check valve supplier in Bangladesh

Service and pump
The fluid, its temperature, working and design pressure, and whether the valve guards a pump outlet, where slam protection matters.
Size, rating and flanges
DN with PN, or NPS with Class, and your pipe's flange standard: EN 1092-1 for PN, EN 1759-1 for Class. In most sizes one will not bolt to the other.
Face-to-face length
The dimension table the valve follows, EN 558 or ISO 5752, so a replacement fills the old gap.
Cracking pressure
The smallest pressure difference between inlet and outlet at which the valve opens. Ask for it on the datasheet, above all for spring-loaded designs on low-pressure lines.
Rating at temperature
For steel bodies, the allowed pressure from the ASME B16.34 table at your working temperature, not only the class name; the standard covers wafer valves too.
Materials and papers
Body, disc, seat and spring materials, EN 10204 type 3.1 certificates for pressure parts, and a test record per lot or serial number.

Standards and tests for check valves

EN 16767
The current European standard for metallic check valves, in its 2020 edition. The 2016 edition is withdrawn, so a quote citing it is out of date.
API 594
The American standard for flanged, lug, wafer and butt-welding check valves. Ask which edition the quoted valve is built and tested to.
EN 1074-3
Fitness-for-purpose requirements and verification tests for check valves in water supply, read with EN 1074-1. Ask for it on drinking-water mains.
ISO 5208 or EN 12266-1
Pressure testing of metallic valves. The record should name the standard, the leakage rate and the serial numbers covered.

What moves the price of a check valve

  • Closing design: a plain swing or lift check usually costs less than a non-slam or spring-assisted one.
  • Size and rating: a larger bore or higher PN or Class needs a heavier body and disc.
  • Materials: cast iron against carbon or stainless steel, and the disc, seat and spring the fluid needs.
  • Papers: a build to EN 16767 or API 594 with type 3.1 certificates and a record per lot.
  • Inspection: tests witnessed at the maker by a third party add cost and time.

Lead times and delivery

We found no published lead time for check valves, so we give no figure. Common sizes held in importers' stock usually arrive soonest. A non-slam design, a large bore, a high class, stainless steel or tests witnessed at the maker usually mean importing to order, which takes longer. Roptan confirms dates and any minimum in the quote.

Each valve arrives capped and tagged to its schedule line, and we match its body markings to the certificates and the order. On import, check valves fall under HS 848130, check (non-return) valves, so the bill of entry should say so. Handover papers: test records, material certificates, the datasheet and a VAT invoice (Mushak 6.3).

What we check for this order

  • Markings against certificatesWe match size, rating, material and heat number on the body, marked to EN 19 or ISO 5209, to the type 3.1 certificate.
  • Test record per lotWe check the record names ISO 5208 or EN 12266-1, the leakage rate and the serial numbers delivered.
  • Design as orderedWe confirm the closing design and cracking pressure on the datasheet match the order: a plain swing check in place of a non-slam one brings back the slam.
  • Stainless gradeFor stainless bodies we ask for PMI, by OES where a low-carbon L grade must be proved, as XRF cannot read carbon.

Questions buyers ask

Which check valve should go on a pump outlet?

Usually a non-slam design. When a pump stops, the flow reverses and a plain swing disc can slam shut; the surge, water hammer, can rupture pumps, valves and pipes. A non-slam check shuts before reverse flow builds up.

What is cracking pressure?

The smallest pressure difference between inlet and outlet at which the valve opens, also called opening pressure. On a low-pressure line, a spring-loaded check that needs more pressure to open can hold back flow, so compare quotes on the datasheet figure.

Which standard suits a check valve on a water main?

For drinking-water supply, ask for EN 1074-3, read with EN 1074-1. Industrial metallic check valves follow EN 16767, and the American standard is API 594. Either way, ask for the test record of the lot you receive.

Does a boiler feed line need a check valve?

Usually yes. Bangladesh's Boiler Rules 2025 name a check valve among the fittings and mountings to be installed before the boiler inspection, which the Office of the Chief Inspector of Boilers carries out. Ask for a valve rated for the feed conditions, with its certificate and test record.

How soon will I hear back about valves?

Within 48 hours of a complete requirement, with a price and a delivery date. A requirement is complete when it has the model or specification, where it is needed and by when.

Who do I deal with?

With Roptan, when Roptan manages the order: we buy from the verified seller and deliver to you. With the supplier directly, when you post on the requirement board and choose a quote yourself.

Other valve products

Each product type has its own page as it is published; until then its card opens the category form.

All valves