Managed sourcing from Bangladesh, for export and for buyers at home
Get it sourced

Machinery and handling · Air compressors

Air receiver supplier in Bangladesh

Use Roptan as your air receiver supplier in Bangladesh. Tell us the volume, design pressure and where the tank will stand: we source receivers from verified sellers, check the code, test certificate and safety valve, and deliver.

  • Verified sellers
  • Checked before it ships
  • Delivered by Roptan

Get air receivers sourced

Prefer to deal with suppliers yourself? Post it on the requirement board

Buying air receivers in Bangladesh

An air receiver is a pressure vessel that stores air delivered by a compressor. It covers peaks in demand, steadies system pressure and lets condensate settle, and after a piston compressor it also damps pulsation. Plants buy receivers with a new compressor, to add storage for a variable speed machine, or to steady pressure at a demanding user far from the compressor room.

Because a receiver holds stored energy, its papers matter more than its paint. As your air receiver supplier in Bangladesh, Roptan asks verified sellers for the design code, the test certificate for the vessel's own serial number and the safety valve setting, checks them against the nameplate, and delivers the receiver.

Kinds of air receiver

Primary (wet) receivers

Stand next to the compressor and take air straight from it, so most condensate collects here. Choose one with every compressor; with piston units it also damps pulsation and cools the air.

Secondary receivers

Placed close to a point of high, intermittent demand. Sized and sited well, one cuts pressure swings across the rest of the plant.

Receivers before the dryer

Some systems use one receiver before the dryer and another near the intermittent users. Choose this layout where peaks would otherwise overload the dryer or drag down plant pressure.

Vertical and horizontal receivers

Choose by the floor area and height you have. Small compressor-mounted tanks also come in pancake and twin-tank shapes for portable workshop units.

What to tell an air receiver supplier in Bangladesh

Volume
The old rule of 1 to 3 gallons per cfm is no longer good practice. Ask the seller to size the receiver against your compressor type, its controls and your demand peaks.
Design pressure and temperature
State maximum working pressure and design temperature, leaving a margin above the compressor's top setting for the safety valve.
Variable speed storage
A variable speed compressor needs enough storage to avoid ramping its speed up and down all day; give its flow so the receiver can be sized for it.
Corrosion allowance
Humid air leaves water in every receiver, and water corrodes steel. Ask for the corrosion allowance in the design.
Drain
An automatic condensate drain, not a manual valve that gets left open. Poorly kept drains waste compressed air.
Safety valve and fittings
A safety or relief valve set so the design pressure cannot be exceeded, plus the openings your piping needs.
Orientation and space
Vertical or horizontal, the floor area and height you have, and indoors or outside.

Codes, tests and papers for air receivers

ASME BPVC Section VIII Division 1
Covers design, fabrication, inspection, testing and certification of vessels above 15 psig; the 2025 edition is current. Ask for the edition and whether the vessel carries the ASME mark.
EN 13445
European unfired pressure vessel standard, harmonised with the Pressure Equipment Directive; Parts 1 and 3 have 2026 editions. Ask which edition the vessel was designed to.
Pressure Equipment Directive 2014/68/EU
Covers EU pressure equipment generally over one litre and above 0.5 bar gauge, with CE marking and a declaration of conformity.
Hydrostatic test certificate
A pressure test with water, preferred to a test with air because far less energy is released if the vessel fails. Ask for it for the vessel's own serial number.
Bangladesh Labour Act 2006, section 71
Your establishment must take the measures needed so pressure plant never exceeds its safe pressure. We found no separate Bangladesh certificate for receivers.

What moves the price of an air receiver

  • Volume and design pressure, which set the vessel's size.
  • Design code and marking: an ASME-marked or CE-marked vessel with full papers, or a tank built to a stated code without the mark.
  • Corrosion allowance in the design for humid air.
  • Fittings in the package: safety valve, automatic drain and the openings your piping needs.
  • Orientation and supports: vertical or horizontal, on legs, saddles or a skid.

Lead times and delivery

We found no published lead time for air receivers in Bangladesh, so we give no figure. Common volumes and pressures usually come sooner than a large or high-pressure vessel built to order, where code papers and testing add time. Roptan confirms dates and any minimum in the quote.

We deliver the receiver to your plant anywhere in Bangladesh. The seller sets it level, connects it to compressor, dryer and piping, fits drain and safety valve, and pressurises it at commissioning. Keep with the vessel: code and edition, design data, hydrostatic test certificate, safety valve set pressure and a VAT invoice (Mushak 6.3).

What we check for this order

  • Nameplate against papersWe check the nameplate's code, design pressure, design temperature and serial number against the data report and certificates.
  • Test certificate for this serialWe ask for the hydrostatic test certificate of the vessel being supplied, not a type certificate for the model.
  • Safety valve settingWe check the safety valve is fitted, its set pressure is stated and it is at or below the vessel's design pressure.
  • Automatic drainWe check an automatic drain is in the package and discharges, so water does not collect and corrode the shell.

Questions buyers ask

Does an air receiver need a boiler certificate in Bangladesh?

We found no such rule. The Boiler Act 2022 defines a boiler as a closed vessel holding more than 25 litres of water that is used only to raise steam, and its registration and use certificate are written for boilers so defined. Labour Act section 71 still requires your plant to stay within safe pressure, so keep the code papers and the hydrostatic test certificate with the vessel.

What size air receiver do I need?

It depends on your compressor type, its controls and how peaky your demand is, which is why the old gallons per cfm rule is no longer good practice. Where peaks are short, a large receiver may let you buy a smaller compressor. Send compressor data and a demand log.

Why fit a second receiver near a machine?

A secondary receiver close to a high, intermittent user supplies its peaks from storage, so pressure across the rest of the plant swings less. Sizing and siting both matter, so give the seller that user's air use and timing, and ask for a check valve before the secondary receiver so stored air cannot flow back into the system.

Is a hydrostatic test better than an air test?

For proving a vessel, yes. If it fails under test, far less energy is released with water than with air. That is why the hydrostatic certificate for your vessel's serial number is the paper to ask for.

How soon will I hear back about air compressors?

Within 48 hours of a complete requirement, with a price and a delivery date. A requirement is complete when it has the model or specification, where it is needed and by when.

Who do I deal with?

With Roptan, when Roptan manages the order: we buy from the verified seller and deliver to you. With the supplier directly, when you post on the requirement board and choose a quote yourself.

Other air compressor products

Each product type has its own page as it is published; until then its card opens the category form.

All air compressors